PROTECTOR OF LED LUMINAIRES AGAINST TRANSIENT OVERVOLTAGES CONNECTION WITH CABLES

#NSB-10-230-C4-DD

New


Notify me when available

PROTECTOR LED SURGE

CONNECTION WITH CABLES

More details

Ensure the life of your LED luminaires and avoid potential claims and damage of the image

Surge protection for LED luminaires, offering a plus of warranty to the end customer in terms of reliability and durability.

BATULED offers a complete solution in this field: wide range of surge protectors.

Currently over 80% of lighting panels are not properly protected.

Recent studies suggest that more than 80% of the boxes for public lighting existing do not incorporate surge protection. For the remaining 20%, the protection in the box is not enough to effectively protect the set of fixtures connected to the box, as through the long runs of cable can also induce surge.

The staggering of the protection it is essential to obtain effective protection. To do this is to establish a first tier of protection in the box lighting (installing a protective robust, with a high discharge capacity to 40 kA, and with protection POP against overvoltages, permanent) and a second step as close as possible to the luminaire(protection fine that complements the first protector).
 

It is estimated that only in Europe there is a park installed more than 500,000 LED luminaires exterior insufficiently protected.

The update of the park installed LED luminaires with surge protection, it is a very profitable investment, both in terms of reduction of maintenance costs, such as of protection of the high investments made.

BATULED offers a wide range of solutions for the effective protection of the installations of outdoor lighting LED.

A good protection

  • reduces the cost of maintenance
  • ensures continuity of service
  • extends the life of the luminaires
  • ensures ROI on LED technology
CertificatesCE & RoHS
Degree of protectionIP20
Mains voltage230/ 400 V
Voltage AC nominal 50/60Hz ( L - N )230V
Load current AC 50/60Hz2.5 To
Tension maxima service ( L1 - L2 )320V
Voltage maximum service ( L1 / L2 - GND )400V
Current maximum discharge ( L1 - L2 )10 KA
Rated current of discharge (L1 - L2)5A
Level of protection voltage (L1 - L2) in≤ 1,8 KV
Fuse previous maximum25 To
Discharge voltage combined10 KV
Capacity of short circuit10 KA
Response time (L1 - L2)25 ns
Response time (L1/L2 - GND)100 ns
Remote indicationNO
Visual indication end of lifeVISUAL LED + DISCONNECTING
Disconnection thermal dynamics (L1/L2 - GND)IF
ConnectionSERIES/PARALLEL
Type of connectionTERMINAL IN - TERMINAL OUT

Attachments:

Scroll